ATL Telecom OM100 User Manual
Page 39

ATL USER GUIDE
OM100 Optical Multiplexer
75
Indicators
Desktop unit
Status (global)
Optical 1 (status)
Optical 2 (status)
Ch1 (status)
Ch2 (status)
Ch3 (status)
Ch4 (status)
Master (configuration)
Test (mode)
Local loop
Loop back
Remote loop
Interfaces available
Desktop unit
Port 1 G.703 120
Ω
Port 2 G.703 120
Ω
Port 3 G.703 120
Ω
Port 4 G.703 120
Ω
Optical Port Choices
Dual fibre multimode
Single fibre single mode
Single fibre (1+1) single mode
Hand held terminal port
Local terminal port specification
Connector
Standard, 9-way D-Type
Electrical Protocol
EIA232 (RS232/V.28)
Default Settings
19200 bps, 8 bit, 1 stop, no parity
Maximum Baud rate
19200 bps.
Suitable equipment
VT100 terminal, palm top PC or dial up modem
8
S P E C I F I C A T I O N S
8
74
ATL USER GUIDE
OM100 Optical Multiplexer
7.7
TEST
7.7.1
Setting data loopbacks
Note: All loopbacks are controllable from either the master, or slave. Loopbacks 1, 2, C1 & D1
are controllable by all OM100 management systems (i.e., local terminal, front panel buttons)
C
2
1
D
TE
ET
NT1
LT
Slave
OM100
Master
OM100
Exchange
Customer
OM100 Mon 01 Nov 2002 00:58:38
Test > Loopbacks
Urgent Alarm:Off Non-Urgent Alarm:On
Subsystem: LT
Port: 1
Loopback to Exchange Loopback To Customer
Towards Master Towards Slave
LL (Loopback 1) [ ] LL (Loopback C) [ ]
RL (Loopback 2) [ ] RL (Loopback D) [ ]
Press Return to Accept or Escape to Cancel
F1 Help F3 Previous Menu F4 Main Menu F5 Previous Channel
F6 Next Channel Use TAB to select fields
Test
Enables various loopbacks.