ATL Telecom OM100 User Manual
Page 38

ATL USER GUIDE
OM100 Optical Multiplexer
73
7.6
SECURITY (CHANGE PASSWORDS)
This section deals with the security of the system. Access to the OM100 is password
protected. All password characters are displayed as asterisks (*), with 
password.
LOST PASSWORD
Fax Atl Telecom technical support on: ++44 2920 500 850 
or send an e-mail to: [email protected]
Function
This field accepts the password currently attributed to the system. When 
the password is recognised (on entry of the final password character) the 
password field is enabled. 
This field always displays its contents as asterisks, and has a maximum 
length of 10 characters. 
This field defaults to null after initial power on
This field is enabled when the operator enters text into the password field
Field
Old Password
New Password
Confirm Password
OM100 Mon 01 Nov 2002 00:57:40
Security > System
Urgent Alarm:Off Non-Urgent Alarm:On Test Active
Old Password [ ]
New Password [ ]
Confirm Password [ ]
Press Return to Accept or Escape to Cancel
F1 Help F3 Previous Menu F4 Main Menu
Security
Change
passwords.
72
ATL USER GUIDE
OM100 Optical Multiplexer
Description
Equipment sends the Alarm Indication Signal when a serious fault occurs 
preventing them transmitting real data. Detecting this signal means there 
is serious fault with equipment upstream of this unit. 
Incoming signal lost. Either the connection between this unit and the 
upstream equipment has been broken, or the upstream equipment 
has failed. 
Incoming data contains a high number of bit errors. Active if more than 
2048 line code violations are detected within one second. 
Incoming data contains a low number of bit errors. Active if more than 2 
line code violations are detected within one second. 
This counter record the total number of line code violations detected.
Counter to record the total time this user port has been in service.
Counter to record the total time this user port has been out of service.
Counter to record the total time this user port has suffered heavy errors.
Counter to record the total time this user port has suffered light errors.
Counter to record the total time this user port has been error free.
These are restable counters useful whilst fixing, or testing the link.
Press F9 to reset the counters.
Field
AIS Detected
LOS Detected
BER > 10E-3
BER > 10E-6
Line Code violations
Available seconds
Unavailable seconds
Severely errored 
seconds
Errored seconds
Error free seconds
Trip counters
7