ATL Telecom OM100 User Manual
Page 26
ATL USER GUIDE
OM100 Optical Multiplexer
49
Description
Each alarm is given a unique number.
Refer to Section 7.1.3.2 for description of the various alarms.
The severity level for each alarm is configurable.
Alarms can be filtered in the alarm screen based on severity level.
The non-urgent and urgent alarms are based on this severity level.
5 (highest priority)
Generate the URGENT alarm.
Fault recorded in the fault log.
4
Generate the URGENT alarm.
Fault recorded in the fault log.
3
Generate the Non-URGENT alarm.
Fault recorded in the fault log.
2
Generate the Non-URGENT alarm.
Fault recorded in the fault log.
1
Fault recorded in the fault log.
0 (lowest priority)
Alarm disabled. Not logged or displayed.
Field
Id
Fault description
level
7
48
ATL USER GUIDE
OM100 Optical Multiplexer
7.1.3
Alarm severity level settings
F5 Default
To restore the default alarm severity level to an alarm – use the cursors to highlight the desired
line, then press F5 to restore its default alarm severity level.
OM100 Mon 01 Nov 2002 00:47:28
Alarm > Severity Level Settings
Urgent Alarm:Off Non-Urgent Alarm:On
Id| Fault Description | Level
001|Cold Boot <1>
002|Warm Boot <1>
003|Failed to program (Fault:%n) <1>
004|Power Fail <5>
005|Security - password rejected <1>
006|Test Active <1>
007|H/W - Configuration Memory Fail <5>
008|H/W - FPGA Configuration Fail <5>
009|Optical Port %n - LOS <5>
010|Optical Port %n - Laser Fault <3>
Press Return to Accept or Escape to Cancel
F1 Help F3 Previous Menu F4 Main Menu F5 Default F7 Previous Page
F8 Next Page
Alarm severity can be individually
programmed for every alarm
Levels 4&5 alarms activate the
URGENT alarm
Levels 2&3 alarms activate
the Non-URGENT alarm
Level 1 alarms are only
recorded in the fault log
Id's 11 to 20 are on screen 2.
Press F8 to scroll down.
Alarms
Status
Displays the current alarm status.
History
Review the fault log. View recorded alarm events.
Severity Level Settings
Set fault level. Configure Urgent & Non urgent
alarm sources.