Audiocodes mp-118 configuration – AltiGen MAXCS 7.0 Update 1 FXS Configuration with AudioCodes User Manual
Page 7
Configuring Analog Extensions with AudioCodes Gateways
Page 7 of 25
AudioCodes MP-118 Configuration
Important!
While working in the AudioCodes configuration application, make sure that Full is always selected
for the Configuration menu, so that you can see all of the menu options. Check this setting after
you log out and log back in, as sometimes the application can reset the menus to Basic mode.
Figure 7: Choose Full for the AudioCodes Configuration menu
Also, make sure you click Submit after each change, and later click Burn, or your configuration changes will be lost
after the gateway is restarted.
1.
Click Configuration in the top left corner (see Figure 7). Select System > Regional Settings and make sure
that the times are set up correctly.
Some analog phones can display the time on the LCD display. The FXS port will update the analog phone’s
time while the phone is ringing. If the time is not configured correctly, then the analog phone’s time will be
incorrect. (The Network Time server can be set up under System > Application Setting.)
2.
Select VoIP > Network > IP Routing Table and confirm that the IP address is 192.168.1.20 (the AudioCodes
IP address from Figure 1), the prefix length, and the network’s gateway IP addresses are set up properly.
(This is a read-only page.)
Figure 8: Check the Network IP Interface settings