Configuring Analog Extensions with AudioCodes Gateways
Page 17 of 25
19.
(Optional) If you want to set up E911 Location ID for relocation for the gateway, select VoIP > GW and IP to
IP > Analog Gateways > Authentication.
For the appropriate ports, enter the information in the User Name field in the following format:
(extension number)xatgnemx(E911 LID)
For example, to specify extension number 200 assigned to Location ID 5, enter the following string:
200xatgnemx5
Enter the extension’s SIP Registration password (from MaxAdministrator) in the Password field (refer to the
chapter Setting Up IP Extensions in the MaxCS 7.0 Update 1 Administration Manual.
For details on configuring E911 Location IDs for IP phones, refer to the chapter Location-Based E911 (for Re-
location) in the MaxCS 7.0 Update 1 Administration Manual.
20.
Submit your last changes. On the toolbar, click Burn to save this configuration.
Figure 26: Click the Burn button.
21.
Reboot your AudioCodes device so that all of the changes take effect. Then proceed to the next section to
verify your settings.
Verification
Now that you have configured both MaxCS 7.0 and AudioCodes, verify that the settings are correct and that the
phones work correctly.
1.
Select VoIP > GW and IP to IP > Hunt Group > Endpoint Phone Number. This table defines phone numbers
for gateway endpoints.
Figure 25: Enter E911 Location ID for each port