3.4.4 CONFIGURATION: COUNT/PULSE.
NOTE: Used with pulse input only. Each pulse in is
multiplied by the count/pulse factor.
1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 7.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 4.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:
1 for 1
2 for 2
5 for 5
7. Press the ENTER switch. The ENTER light turns off.
COUNT/PULSE
FLASH ON OFF (Enter Light)
Set 1x 7 4 1 (Thumbwheel Switch)
Set 2x 7 4 2 (Thumbwheel Switch)
Set 5x 7 4 5 (Thumbwheel Switch)
3.5 INITIALIZE SYSTEM TO ORIGINAL FACTORY SETTINGS
The printer can be reset to its original settings by the
INITIALIZE function.
1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 8.
3. Press the ENTER switch. The ENTER light flashes.
4. Press the ENTER switch. The ENTER light turns on.
5. Press the ENTER switch 2 more times.
6. The ENTER light turns off.
INITIALIZE SYSTEM
FLASH ON ON OFF
INITIALIZE 8 8 8 8
REMEMBER: Return the thumbwheel switch to the correct mode