Industrial Data Systems IDS 152 User Manual
Page 19
3.2.10 CONFIGURATION: PRINT SIZE.
1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 2.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 3.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:
0 for Host Control of Print Size.
1 for NORMAL SIZE PRINT.
2 for ENHANCED SIZE PRINT (double width).
3 for MIXED SIZE PRINT (numbers large,
letters small).
7. Press the ENTER switch. The ENTER light turns off.
PRINT SIZE
FLASH ON OFF (Enter Light)
Host Control of Size 2 3 0 (Thumbwheel Switch)
Normal Size Print 2 3 1 (Thumbwheel Switch)
Enhanced Size Print 2 3 2 (Thumbwheel Switch)
Mixed Size Print 2 3 3 (Thumbwheel Switch)
3.2.11 CONFIGURATION: STATION NUMBER.
The station number is enabled when it is set. Setting the
station number to 0 disables it.
1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 2.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 4.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:
0 for STATION NUMBER = DISABLED.
1 for STATION NUMBER = 1.
9 for STATION NUMBER = 9.
7. Press the ENTER switch. The ENTER light turns off.
SET STATION NUMBER
FLASH ON OFF (Enter Light)
Disable Station No. 2 4 0 (Thumbwheel Switch)
Set Station No. = 1 2 4 1 (Thumbwheel Switch)
Set Station No. = 9 2 4 9 (Thumbwheel Switch)
REMEMBER: Return the thumbwheel switch to the correct mode