2.5.1 PRINT WEIGHT.
Press the
PRINT Switch to print the weight on the scale in the
form:
WEIGHT 12345 LB
2.5.2 PRINT WEIGHTS WITH GROSS, AND TARE LABELS.
The
PRINT Switch prints the weight on the scale in the form:
GROSS 12345 LB
The
AUX Switch prints the weight on the scale in the form:
TARE 2000 LB
2.5.3 GROSS, TARE, NET PRINTING.
This feature provides gross, tare, and net printing
in 2 weighments.
The
AUX Switch instructs the printer store the weight on the
scale into the tare register. The printer cycles to signal
that tare weight is read.
The
PRINT Switch causes the printer to print the GROSS, TARE,
and NET weights.
GROSS 4321 LB
TARE 1234 LB
NET 3087 LB
2.5.4 PRINT AND TOTAL.
This feature provides a totalize register for summing
weighments.
The
PRINT Switch prints the weight on the scale. The printer
adds the weight to the total register.
The
AUX Switch prints the total.
Press the
AUX Switch twice within 10 seconds to clear the total
register. The print head will cycle at the end of 10 seconds
to signal that the printer is ready for new commands.