Using the Adaptec RAID Configuration Utility
●
54
System Shutdown Rebuild
Note:
This section applies only when an operating system and drivers
are installed.
You can shut down the system and replace the failed drive with a new
one (of equal or greater capacity). When the system is booted, you can
assign the new drive as a spare, and this will start the Rebuild task. All
the data from the good drive is copied to the new one, and the original
RAID 1 array is recreated.
Manual Rebuild
1
From the Main Menu, select Manage Arrays. From the List of
Arrays, select the array you want to Rebuild.
2
Press Ctrl+R to Rebuild.
Verifying Arrays
If you are notified of a mismatch of data during a RAID 1 build, follow
these steps to verify the arrays:
Note:
The Verify option is available only if the array is Optimal. If the
array has failed, you must rebuild the array.
1
Highlight the array you want to verify.
2
Press Ctrl+S.
3
When the Verify is complete, you are notified of any errors found
during the Verify operation.