Configure disk drives, Rebuilding arrays, Configure disk drives rebuilding arrays – Adaptec 48300 User Manual
Page 53
Using the Adaptec RAID Configuration Utility
●
53
Configure Disk Drives
Caution:
If the drive is used in an array, you may not be able to use
the array again. Do not configure a drive that is part of a boot array.
To determine which disks are associated with a particular array, see
Viewing Array Properties on page 51
You will not be able to configure the drive if there is a legacy
partition table or valid Master boot record (MBR) already existing.
You will need to run a disk partitioning software like Fdisk to delete
the partition.
To configure drives:
1
From the Main menu, select Configure Drives.
2
Use the up and down arrow keys to highlight the disk you wish to
configure, then press Insert.
3
Repeat
if you want to add another drive to be configured.
4
Press Enter.
5
Read the warning message and ensure that you have selected the
correct disk drives to configure. Type Y to continue.
Rebuilding Arrays
Note:
Rebuilding applies to Fault Tolerant arrays (RAID 1 and
RAID 10) only. If a spare does not exist and a disk drive fails, you need
to create a spare before you can rebuild an array. See
before continuing your Rebuild.
By replacing a failed drive of a RAID 1 array with a new drive, you can
Rebuild to get the array to Optimal status and assume fault tolerance.
You can perform a Rebuild in the following ways:
!