Troubleshooting

Radar Tank Gauge

82

Installation and Operations Manual

Error

Output

Possible cause

Remedy

If the surface

is not calm

(e.g. filling,

emptying, agi-

tator run-

ning), the

measured

value

jumps sporad-

ically to a

higher

level

Signal is weakened

by the rough

surface — the

interference

echoes

are sometimes

stronger

1. Carry out tank mapping

basic setup

2. Set the process cond. (004) to

"turb. surface" or

"agitator"

3. Increase the output damping

(058)

4. Optimize the orientation

5. If necessary, select a better

mounting position

and/or larger antenna

During filling/

emptying

the measured

value jumps

downwards

Multiple echoes

yes

1. Check the tank shape (002),

e.g. "dome ceiling" or

"horizontal cyl"

2. In the range of the blocking dist.

(059) there is no echo evalua-

tion

Adapt the value

3. If possible, do not select

central installation position

4. Perhaps use a stilling well

E 641 (loss of

echo)

Level echo is too

weak.

Possible causes:

• Rough surface

due to filling/

emptying

• Agitator running

• Foam

yes

1. Check application parameters

(002), (003) and (004)

2. Optimize alignment

3. If necessary, select a better

installation position and/or

larger antenna

E 641 (loss of

echo) after

turn on the

power supply

If the instrument is configured to Hold

by loss of echo the output is set to any

value/current.

noise level during

the initialisation

phase to high.

Repeat once more empty calibr.

(005).

Caution!

Before conformation change with

O

or

S

to the edit mode.

20 mA/100%

4 mA/0%

t

actual

expected

20 mA/100%

4 mA/0%

t

expected

actual

20 mA/100%

4 mA/0%

t

expected

actual

20 mA/100%

E 641

4 mA/0%

t

actual

expected