beautypg.com

Measuring range – Lightning Audio 7532 User Manual

Page 15

background image

15

7532

Mounting

Measuring range

The usable measuring range depends on the size of the antenna, the reflectivity of the

medium, the mounting location, and eventual interference reflections.

The following tables describe the groups of media as well as the achievable measuring

range as a function of application and media group. If the dielectric constant of a

medium is unknown, it is recommended to assume media group B to ensure a reliable

measurement.

1)Treat Ammonia NH3 as a medium of group A, e.g. always use a stilling well.

Measuring range depending on product class for 7532 RTG:

Product class

DK (

ε

r)

Examples

A

1.4 … 1.9

non-conducting liquids, e.g. liquefied gas

1)

B

1.9 … 4

non-conducting liquids, e.g. benzene, oil, toluene, …

C

4 … 10

e.g. concentrated acids, organic solvents, esters, aniline,

alcohol, acetone, …

D

> 10

conducting liquids, e.g. aqueous solutions, dilute acids and

alkalis

Product class

Stilling well/ Bypass

Measuring range

7532 RTG

> DN150

A

DK(

ε

r)=1,4…1,9

38 m/124 ft

B

DK(

ε

r)=1,9…4

38 m/124 ft

C

DK(

ε

r)=4…10

38 m/124 ft

D

DK(

ε

r)>10

38 m/124 ft

max. measuring

range with custody

transfer approvals

20 m/65 ft