2 system error messages, System error messages – Lightning Audio 7532 User Manual
Page 79

79
7532
Troubleshooting
9.2
System error messages
Code
Description
Possible cause
Remedy
A102
checksum error
general reset & new
calibr.required
device has been powered off
before data could be stored;
emc problem; E²PROM defect
reset;
avoid emc problem; if
alarm prevails after reset,
exchange electronics
W103
initialising - please
wait
E²PROM storage not yet
finished
wait some seconds; if
warning prevails, exchange
electronics
A106
downloading please
wait
processing data download
wait until warning
disappears
A110
checksum error
general reset & new
calibr.required
device has been powered off
before data could be stored;
emc problem; E²PROM defect
reset;
avoid emc problem; if
alarm prevails after reset,
exchange electronics
A111
electronics defect
RAM defective
reset;
if alarm prevails after
reset, exchange electronics
A113
electronics defect
ROM defective
reset;
if alarm prevails after
reset, exchange electronics
A114
electronics defect
E2PROM defective
reset;
if alarm prevails after
reset, exchange electronics
A115
electronics defect
general hardware problem
reset;
if alarm prevails after
reset, exchange electronics
A116
download error
repeat download
checksum of stored data not
correct
restart download of data
A121
electronics defect
no factory calibration existant;
E²PROM defective
contact service
W153
initialising - please
wait
initialisation of electronics
wait some seconds; if
warning prevails, power off
device and power on again
A155
electronics defect
hardware problem
reset;
if alarm prevails after
reset, exchange electronics
A160
checksum error
general reset & new
calibr.required
device has been powered off
before data could be stored;
emc problem; E²PROM defect
reset;
avoid emc problem; if
alarm prevails after reset,
exchange electronics
A164
electronics defect
hardware problem
reset;
if alarm prevails after
reset, exchange electronics
A171
electronics defect
hardware problem
reset;
if alarm prevails after
reset, exchange electronics
A231
sensor 1 defect
check connection
HF module or electronics
defective
exchange HF module or
electronics
Table 3: System error messages