5 mounting with sample hatch on stilling well, Installation tips – Lightning Audio 7532 User Manual
Page 23

23
7532
Mounting
3.4.5
Mounting with Sample hatch on stilling well
Installation tips
For control and cleaning purposes as well as for hand dipping (tape), a sample hatch
gauging is recommended. The sensor head can be easily checked in the area of the
opening. Manual gauging with gauge rod or tape is possible without removal of the
transmitter. The lower edge of the opening is the reference for the gauging. The
construction is only suitable for non-pressurized operation.
Note!
The nozzle for manual gauging is not part of the standard offering from Varec. Please
contact Varec for further information.
2)Only dimensions adapted to standard. Designed for non-pressurized operation only,
therefore thickness of flange can be reduced (e.g. 8mm).
Flange
DN150
DN200
DN250/300
Flange
ANSI 6"
ANSI 8"
ANSI 10"
PN [lbs]
2)
16
16
16
PN [lbs]
2)
150
150
150
A [mm]
110
140
170
A [mm]
110
140
170
L [mm}
—
300
450
L [mm]
—
300
450
L0
0-FM
R5
3xxx-06
-00
-0
0-en-00