background image

Commissioning

Radar Tank Gauge

56

Installation and Operations Manual

Display "dist./meas.value (008)"

The distance measured from the reference point to the product surface and the level

calculated with the aid of the empty alignment are displayed again. Check whether the

values correspond to the actual level or the actual distance. The following cases can

occur:
• Distance correct – level correct -> basic setup completed
• Distance incorrect – level incorrect -> a further interference echo mapping must be

carried out "check distance" (051).

• Distance correct – level incorrect -> check "empty calibr." (005)

Function "history reset" (009)

By this function a history reset of the device is performed, i.e. the correspondence table

between level an index values is deleted. A new correspondence table will be filled and

stored after the history reset, see page 57.

Caution!

Perform only after first installation (see »Function "auto-correction" (031)« on page 57).

In this case also effect a reset of the dip table in function "dip table mode" (033).

Note!

After basic calibration, it is wise to evaluate the measurement using the envelope curve

(function group "display" (09)).

E

+

E

+

After 3 s, the following message appears

E

+