beautypg.com

Fault finding, X-006-a – HP COMBI 2180206H User Manual

Page 31

background image

9

Combi HP thermostatic mixer shower

X-006-A

Turn the control knob anti-clockwise.

Turn the control anti-clockwise.

Reduce the simultaneous demand from

supply — make sure a dedicated supply

to mixer.

Contact Customer Service for advice on

flow regulators.

Clean – refer to ‘Flushing Procedure’.

Turn the temperature control clockwise.

(Override the max. temperature stop if

necessary).

Turn the temperature control clockwise.

(Override the max. temperature stop if

necessary).

Make sure heating cylinder is set to

maximum hot water output.

Contact Triton Customer Service for

advice on flow regulators.

Clean – refer to ‘Flushing Procedure’.

Check water elsewhere in house and if

necessary contact local water company.

Inspect the flow regulators (if fitted) and

the check valves – refer to ‘Flushing

Procedure’. Clean if necessary.

Clean showerhead.

Reduce the simultaneous demand —

make sure a dedicated supply to mixer.
Make sure service valves are fully open.

Turn off the shower and consult a

competent plumber or contact Triton

Customer Service.

Turn off the shower and consult a

suitably competent plumber.

Renew cartridge (internal seals are not

serviceable).

1.1.1

1.2.1

1.3.1

1.4.1

1.5.1

2.1.1

2.2.1

2.3.1

2.4.1

2.5.1

3.1.1

3.2.1

3.3.1

3.4.1

3.4.2

4.1.1

5.1.1

6.1.1

Not enough cold

water flowing

through shower.

Increase in the

ambient cold

water

temperature.

High volume of

cold water

drawn off

elsewhere.

Excessive flow

rate.

Dirty check

valves.

Not enough hot

water flowing

through shower.

Decrease in the

ambient cold

water

temperature.

Not enough hot

water supplied

from the heating

appliance.

Excessive flow

rate.

Dirty check

valves.

Water supplies

cut off.

Shower unit

blocked.

Showerhead

blocked.

Reduced flow

rate when other

outlets in use.

Water supply

blocked or

restricted.

Blockage in

pipework.

Pipework not

flushed before

connecting the

unit(‘O’ rings

damaged).

1.1

1.2

1.3

1.4

1.5

2.1

2.2

2.3

2.4

2.5

3.1

3.2

3.3

3.4

4.1

5.1

6.1

Water too hot.

Water too cold.

Water does not

flow or shower

pattern collapses

when another

outlet is turned on.

Water too cold or

too hot.

Water does not

flow or shower

pattern collapses

when another

outlet is turned on.

Shower will not

shut off.

1

2

3

4

5

6

FAulT FIndInG

FAULT FINDING

Problem/Symptom Cause

Action/Cure