Troubleshooting – Heath Zenith SL-6107 User Manual
Page 12

595-4514-13
-12-
Light will not come on:
• Circuit breaker is off.
Turn breaker back on.
• Bulb is burned out.
Replace light bulb.
• Photo Sensitivity is set to DARK.
Rotate the adjustment clock-
wise towards the LIGHT position.
• Control is in the “Off” position.
Set to Auto or On.
• Control may be wired incorrectly.
See Troubleshooting Wiring
Connections, page 7.
Light will not turn off:
• Control is in the “On” position.
Set to Auto or Off.
• Control time period set too long.
Set to shorter time period.
• Control may be wired incorrectly.
See Troubleshooting Wiring
Connections, page 7.
Remote switch does not work:
• The remote switch only works to turn the light on in the Auto
mode.
Put sensor in the Auto mode.
• Control may be wired incorrectly.
See Troubleshooting Wiring
Connections, page 7.
In Auto mode, light comes on randomly:
• Objects in detection area which heat and cool, such as air vents
or appliances, may trigger the control. Also, check wiring.
See
Troubleshooting Wiring Connections, page 7.
• The remote switch may have been flipped on.
In the Auto mode, light does not turn on:
• If there is too much light already in the room, the light may not
come on.
Turn the Photo control clockwise towards the any light
level position.
TROUBLESHOOTING