Replacement
Motion Sensor

Requirements

• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must

be wired through a switch.

Some codes require installation by a qualifi ed

electrician.

© 2007 HeathCo LLC

598-1155-01

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight

hours.

• LED indicates motion was sensed (day or

night).

Model SH-5407

OPERATION

Move ON-TIME Switch

to 1, 5, or 10 minutes

Mode Switching Summary

Flip switch off for

one second then

back on*

* resets to Auto Mode at dawn.

TEST

AUTO

MANUAL MODE

ON-TIME

ON-TIME

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time (1

1

/

2

min.) the control will be in the

AUTO mode.

10 5 1 TEST

10 5 1 TEST

MANUAL MODE

AUTO

TEST

... back on.

1 Second OFF

then...

Manual mode only works at night
because daylight returns the sen-
sor to AUTO.

Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.

Manual mode works only with
the ON-TIME switch in the 1, 5,
or 10 position.

Note: When fi rst turned on wait about 1

1

/

2

minutes

for the circuitry to calibrate.

Put the ON-TIME switch in the 1,
5, or 10 minute position.

Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Normal

1, 5, 10 min.

x

Manual

Until Dawn*

x