Heath Zenith SL-5512 User Manual
Twin halogen motion sensing light, Operation, Model sl-5512
© 2008 HeathCo LLC
595-5575-09
Model SL-5512
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• D
ual
B
rite
®
Timer.
• Photocell keeps the lighting off during daylight
hours.
• LED indicates motion was sensed (day or night).
Cover
Plate
Light Control
Sensor
3 Wire
Connectors
Gasket
6 Mounting
Screws (3 sizes)
Mounting Bolt
Mounting Strap
Rubber Plug
Light Shield
Plastic Hanger
2 Halogen Bulbs
This package includes:
D
ual
B
rite
®
Twin Halogen
Motion Sensing Light
TEST
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to
Dawn
D
ual
B
rite
®
Put ON-TIME switch
on the sensor bottom
to TEST and the D
ual
-
B
rite
®
switch OFF.
OPERATION
* resets to Auto Mode at dawn.
ON-TIME
TEST
1 5 20
... back on.
1 Second OFF
then...
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
•
Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Mode:
On-Time
Works: Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
AUTO
MANUAL MODE