Flue system approvals and installations – Heat & Glo Fireplace 2197-980 User Manual

Page 30

background image

Heat & Glo • SOHO-N-AUB • 2197-980 Rev. G • 2/13

30

Figure 7.8 Flue Components and Terminations

MODEL

SOHO-N-AUB

FLUE TERMINATION APPROVALS

SLP-TRAP2 HORIZONTAL TERMINATION CAP

SLP-TVHW VERTICAL TERMINATION CAP

DVP-FBHT HORIZONTAL TERMINATION CAP

Flue System Approvals And Installations

These models have flue starting collars on both the top

and the back of the unit. Depending upon the installation,

decide which ONE set of starting collars will be used to at-

tach the flue system. The starting collar sealing cap must

remain on the starting collar NOT used.
These models use SLP series direct flue components.
Approved flue system components are labeled for identi-

fication.

NO OTHER FLUEING SYSTEMS OR COMPO-

NENTS MAY BE USED. Detailed installation instructions

are included with each flue termination kit and should be

used in conjunction with this manual. Figure 7.8 shows

flue system components and terminations.
Identifying Flue Components
The flue systems installed on this gas fireplace may include

one, two, or three 90°

elbow assemblies. The relationships

of vertical rise to horizontal run in flue configurations using

90° elbows

MUST BE strictly adhered to. The rise to run

relationships are shown in the flueing drawings and tables

on the next few pages.
WARNING! Risk of Fire! This gas appliance and flue as-

sembly must flue directly to the outside and must never

be attached to a chimney serving a separate solid fuel

burning appliance. Each gas appliance must use a sepa-

rate flue system-common flue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible

materials beyond the minimum clearances. Comply with

all minimum clearances to combustibles as specified in

this manual. Overlapping material could ignite and will in-

terfere with proper operation of doors and louvers.
• Horizontal sections 3 in. (76 mm) from the top of the

pipe.

• Horizontal sections 2-1/2 in. (64 mm) at wall shield

firestops.

• Horizontal sections 1 in. (25 mm) from sides and bottom

of the pipe.

• Vertical sections 1 in. (25 mm) on all sides of pipe.

Failure to keep insulation or other material away from

vent pipe may cause over heating and fire.
For alternative installations, other than depicted, contact

your dealer for further information.

HORIZONTAL

TERMINATION

WALL FIRESTOP

90 DEGREE

ELBOW

VERTICAL

TERMINATION

STORM COLLAR

ROOF FLASHING

HORIZONTAL PIPE

SUPPORT

PIPE LENGTH

WALL BRACKET

CEILING

FIRESTOP

SLP-TVHW

SLP-TRAP2

SLP SERIES

Flue system termination kits

DVP-FBHT