Flue system approvals and installations – Heat & Glo Fireplace 2197-980 User Manual
Page 30

Heat & Glo • SOHO-N-AUB • 2197-980 Rev. G • 2/13
30
Figure 7.8 Flue Components and Terminations
MODEL
SOHO-N-AUB
FLUE TERMINATION APPROVALS
SLP-TRAP2 HORIZONTAL TERMINATION CAP
SLP-TVHW VERTICAL TERMINATION CAP
DVP-FBHT HORIZONTAL TERMINATION CAP
Flue System Approvals And Installations
These models have flue starting collars on both the top
and the back of the unit. Depending upon the installation,
decide which ONE set of starting collars will be used to at-
tach the flue system. The starting collar sealing cap must
remain on the starting collar NOT used.
These models use SLP series direct flue components.
Approved flue system components are labeled for identi-
fication.
NO OTHER FLUEING SYSTEMS OR COMPO-
NENTS MAY BE USED. Detailed installation instructions
are included with each flue termination kit and should be
used in conjunction with this manual. Figure 7.8 shows
flue system components and terminations.
Identifying Flue Components
The flue systems installed on this gas fireplace may include
one, two, or three 90°
elbow assemblies. The relationships
of vertical rise to horizontal run in flue configurations using
90° elbows
MUST BE strictly adhered to. The rise to run
relationships are shown in the flueing drawings and tables
on the next few pages.
WARNING! Risk of Fire! This gas appliance and flue as-
sembly must flue directly to the outside and must never
be attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance must use a sepa-
rate flue system-common flue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping material could ignite and will in-
terfere with proper operation of doors and louvers.
• Horizontal sections 3 in. (76 mm) from the top of the
pipe.
• Horizontal sections 2-1/2 in. (64 mm) at wall shield
firestops.
• Horizontal sections 1 in. (25 mm) from sides and bottom
of the pipe.
• Vertical sections 1 in. (25 mm) on all sides of pipe.
Failure to keep insulation or other material away from
vent pipe may cause over heating and fire.
For alternative installations, other than depicted, contact
your dealer for further information.
HORIZONTAL
TERMINATION
WALL FIRESTOP
90 DEGREE
ELBOW
VERTICAL
TERMINATION
STORM COLLAR
ROOF FLASHING
HORIZONTAL PIPE
SUPPORT
PIPE LENGTH
WALL BRACKET
CEILING
FIRESTOP
SLP-TVHW
SLP-TRAP2
SLP SERIES
Flue system termination kits
DVP-FBHT