26

Top Vent - Horizontal Termination

Figure 7.3

H

2

H

1

V

1

INSTALLED

HORIZONTALLY

Figure 7.4

One Elbow

Two Elbows

V

1

H

1

V

1

Minimum

H

1

+ H

2

Maximum

Elbow only

Not Allowed

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

5 ft.

1.52 m

3 ft.

914 mm

8 ft.

2.44 m

4 ft.

122 mm

11 ft.

3.35 m

5 ft.

152 mm

14 ft.

4.27 m

V

1

+ H

1

+ H

2

Maximum = 38 ft. (11.58 m)

H

1

+ H

2

Maximum = 14 ft. (4.27 m)

V

1

Minimum

H

1

Maximum

Elbow only

2 ft.

610 mm

1 ft.

305 mm

2-1/2 ft.

762 mm

2 ft.

610 mm

5-1/2 ft.

1.68 m

3 ft.

914 mm

9 ft.

2.74 m

4 ft.

1.22 m

12 ft.

3,66 m

5 ft.

1.52 m

15 ft.

4.57 m

V

1

+ H

1

Maximum = 38 ft. (11.58 m)

H

1

Maximum = 15 ft. (4.57 m)

Note: A 6 in. (152 mm) section of straight flue must be at-

tached to the fireplace before a 90° elbow.

Note: A 6 in. (152 mm) section of straight flue must be

attached to the fireplace before a 90° elbow.