beautypg.com

Hoshizaki KM-61BAH User Manual

Page 22

background image

17

1-800-233-1940 for recommendations. Keep in mind that setting the harvest timer to a
longer setting will decrease 24 hour production.

Dip Switch Setting

Time

(seconds)

No. 1

No. 2

OFF

OFF

60

ON

OFF

90

OFF

ON

120

ON

ON

180

c) Drain Timer (S1 dip switch 3 & 4)

Once every ten freeze cycles, the drain valve opens to drain the water tank for the
time determined by the drain timer. These switches also determine the time to delay
completion of a defrost cycle, i.e. the minimum defrost time.
Do not change this setting, or the unit will not operate properly or produce high quality
ice.

Dip Switch Setting

Time (seconds)

No. 3

No. 4

T1

T2

OFF

OFF

10

120

ON

OFF

10

180

OFF

ON

20

120

ON

ON

20

180

T1: Time to drain the water tank
T2: Harvest timer at drain

Drain cycle always occurs on the 2nd harvest after startup. Then, depending on the
drain frequency control setting (dip switch 5 & 6), drain cycle occurs every cycle, or
every 2nd, 5th, or 10th cycle.

d) Drain Frequency Control (S1 dip switch 5 & 6)

The water tank drains at the frequency set by the drain frequency control.
The drain frequency control is factory-adjusted to drain the water tank every 10 cycles,
and no adjustment is required. However, where water quality is bad and the icemaker
needs a drain more often, the drain frequency can be adjusted as shown in the table
below.

Dip Switch Setting

Frequency

No. 5

No. 6

OFF

OFF

every cycle

ON

OFF

every 2 cycles

OFF

ON

every 5 cycles

ON

ON

every 10 cycles