598-1351-01
TEST AND ADJUSTMENT
❒
Turn on the circuit breaker and light switch.
❒
For each sensor, loosen the
clamp screw in the sensor ball
joint and gently rotate the sen-
sor.
❒
Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area.
Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 360° (180° each sensor)
Electrical Load . . . . . . Up to 300 Watt Maximum Tung-
sten [Up to 150 Watt maximum
each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
NOTE: Sensors have a 1
1
/
2
minute warm up period
before they will detect motion. When first turned
on, wait 1
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where
pets or traffic may trigger the control.
•
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Least Sensitive
Most Sensitive
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
Maximum Range
Maximum
per Sensor
Coverage Angle
per Sensor
Maximum Range
Maximum
both Sensors
Coverage Angle
both Sensors
RANGE
10 5 1 TEST
ON-TIME
MAX
MIN
RANGE
ON-TIME
10 5 1 TEST
MINUTES
MIN
MAX
NOTE: Meets the ENERGY STAR
®
guidelines when used
with 120 W Max bulbs.
❒
Turn the RANGE control to the mid position (halfway
between MIN and MAX) and the ON-TIME control
to the TEST position.
Motion
Motion
180°
360°
Sensor
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aim-
ing the sensors down will reduce coverage distance.
The sensors are less sensitive to motion directly towards
them.