Mount the light control, Wire the light control – Heath Zenith MSL360FWPB User Manual
Page 3
3
598-1351-01
Mount the Light Control
❒
Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒
Align the three slots in the decorative shell with the
lamp holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
Lock Nut
To avoid water damage and
electrical shock, keep lamp
holders 30° below horizontal.
❒
Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the flood
lamps, do not overtighten.
Keep lamps at least
1" (2.5 cm) from
both sensors. Do not
allow the lamps to
block either lens.
Lens
❒
Push the rubber plug firmly into place.
❒
If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.
Shell Slot
Black to Black
White to White
Gasket
Connect any fixture ground wire(s) to the junction
box ground wire.
Wire the Light Control
Rubber Plug
Mounting
Bolt
WARNING: Turn power off at circuit breaker
or fuse.
❒
Remove the existing light fixture.
❒
Install mounting strap to junction box using screws
appropriate for your junction box.
❒
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒
Thread all fixture wires through the large holes in
the gasket as shown.
❒
Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with
wire connectors.