beautypg.com

Mount the light control, Wire the light control – Heath Zenith MSL360FWPB User Manual

Page 3

background image

3

598-1351-01

Mount the Light Control

Align the light control cover plate and cover plate

gasket. Secure with the mounting bolt.

Align the three slots in the decorative shell with the

lamp holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.

Lock Nut

To avoid water damage and
electrical shock, keep lamp
holders 30° below horizontal.

Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the flood
lamps, do not overtighten.

Keep lamps at least
1" (2.5 cm) from
both sensors. Do not
allow the lamps to
block either lens.

Lens

Push the rubber plug firmly into place.

If a wet location junction box was not used, caulk

the wall plate mounting surface with silicone
weather sealant.

Shell Slot

Black to Black

White to White

Gasket

Connect any fixture ground wire(s) to the junction
box ground wire.

Wire the Light Control

Rubber Plug

Mounting

Bolt

WARNING: Turn power off at circuit breaker

or fuse.

Remove the existing light fixture.

Install mounting strap to junction box using screws
appropriate for your junction box.

The plastic hanger can be used to hold the fixture

while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.

Thread all fixture wires through the large holes in

the gasket as shown.

Connect the junction box wires to the light fixture

wires as shown. Twist together and secure with
wire connectors.