beautypg.com

Performance data – Hoshizaki F043-809 KMD-410MWH User Manual

Page 29

background image

25

4. PERFORMANCE DATA

[a] KMD-410MAH

WATER TEMP. (ºF/ºC)

AMBIENT

TEMP. (ºF/ºC)

50/10 70/21 90/32

70/21

415

188 388 176 354 160

80/27 395

179 353 160 320 145

APPROXIMATE ICE
PRODUCTION PER 24 HR.

90/32 388

176

324

147 289 131

lbs./day kg./day 100/38

382

173 316 143 257 117

70/21

710

731 753

80/27 726 758 776

APPROXIMATE ELECTRIC
CONSUMPTION

90/32 731 780

801

watts 100/38

733

785

820

70/21

148

0.56 126 0.48 114 0.43

80/27 131

0.50 97 0.37 95 0.36

APPROXIMATE WATER
CONSUMPTION PER 24
HR.

90/32 126

0.48

73

0.28 67 0.25

gal./day m

3

/day 100/38

101

0.38 72 0.27 61 0.23

70/21

27

29 32

80/27 28

31

34

FREEZING CYCLE TIME

90/32 29

34

37

min. 100/38

29

34

40

70/21

3.0

2.7 2.6

80/27 2.8

2.3

2.4

HARVEST CYCLE TIME

90/32 2.7

2.0

2.0

min. 100/38

2.4

2.0

2.0

70/21

216

15.2 237 16.7 261 18.4

80/27 232

16.3 265 18.6 287 20.2

HEAD PRESSURE

90/32 237

16.7

288

20.2 311 21.9

PSIG kg/cm

2

G 100/38

240

16.9 293 20.6 333 23.4

70/21

45

3.2 48 3.3 52 3.6

80/27 47

3.3 51 3.6 55 3.9

SUCTION PRESSURE

90/32 48

3.3

54

3.8 58 4.1

PSIG kg/cm

2

G 100/38

49

3.4 55 3.9 62 4.4

TOTAL HEAT OF REJECTION FROM CONDENSER

6,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

Note: Pressure data is recorded at 5 minutes into freezing cycle.

The data not in

bold

should be used for reference only.

We reserve the right to make changes in

specifications and design without prior notice.