Troubleshooting

• When the interior portion has become overheated, for safety

purposes, the power source is automatically turned off, and the indicator lamps
may also be turned off. In such a case, press the “O” (off) side of the power
switch, and wait at least 45 minutes. After the projector has sufficiently cooled
down, please make confirmation of the attachment state of the lamp and lamp
cover, and then turn the power on again.

NOTE

POWER TEMP

LAMP SECURITY

SHUTTER

Description

Blinking

In

Red

or

Lighting

In

Red

Blinking

In

Red

Turned

off

Turned

off

Turned

off

The cooling fan is not operating.

Please turn the power off, and allow the projector to
cool down at least 20 minutes. After the projector has
sufficiently cooled down, please make confirmation that
no foreign matter has become caught in the fan, etc.,
and then turn the power on again.
If the same indication is displayed after the remedy,
please contact your dealer or service company.

Blinking

In

Red

or

Lighting

In

Red

Lighting

In

Red

Turned

off

Turned

off

Turned

off

The internal temperature is rising too much.

Turn the projector off (

20) soon, and allow it to cool

down for 20 minutes or more. After cooling, perform the
following check.
- Are there any obstacles to ventilation around the
projector?
- Does the temperature around the projector exceed the
limit specified? (

77)

When this message is displayed without the obstacles

mentioned above, replacement of the filter unit is

required. Replace the filter unit soon according to the

procedure directed in the paragraph "Filter unit" in the

chapter "Maintenance" (

69). Remember resetting the

FILTER TIME is needed soon after replacement of the

filter unit.

Lighting

In

Green

Simultaneous

blinking in

Red

Turned

off

Turned

off

Replacement of the filter unit is required.

The value of the timer of the FILTER TIME reached the
preset value of the FILTER MESSAGE on the SERVICE
menu under the OPTION menu (

50). Replace the

filter unit soon according to the procedure directed in the
paragraph "Filter unit" in the chapter "Maintenance" (

69).

Remember resetting the FILTER TIME is needed soon
after replacement of the filter unit.

Lighting

In

Green

Alternative

blinking in

Red

Turned

off

Turned

off

There is a possibility that the interior portion has

become overcooled.

Please use the unit within the usage temperature
parameters (5°C to 35°C). After the treatment, reset the
power to on.

Blinking

in

Green

for

approx.

3

seconds

Turned

off

Turned

off

Turned

off

Turned

off

At least 1 “Power ON” schedule is saved to the

projector.

(Please refer to the User’s Manual - Network Guide:
Schedule Settings for more information.)

This manual is related to the following products: