beautypg.com

Listing and code approvals – Hearth and Home Technologies Direct Vent Gas Appliance CNXT4236IT User Manual

Page 7

background image

Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08

7

C. BTU Specifi cations

MODELS: CNXT4236IT, CNXT4842IT, CNXT4236IH,

CNXT4842IH, CNXT4236ILT, CNXT4842ILT,
CNXT4236ILH, CNXT4842ILH

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Vented Gas Fireplace Heaters

STANDARD: ANSI Z21.88-2005•CSA2.33-2005•UL307B

This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Fireplaces for Use
at High Altitudes”.

E. Non-Combustible Materials Specifi cation

Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC
and UL763 shall be
considered non-combustible materials.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.

When installing above 2000 feet elevation:

• In the USA: Reduce input rate 4% for each 1000 feet

above 2000 feet.

• In CANADA: Reduce input rate 10% for elevations

between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.

Check with your local gas utility to determine proper
orifi ce size.

NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.

1

1

Listing and Code Approvals

A. Appliance Certifi cation

CNXT Series

CNXT4236

CNXT4842

IPI

Max/Min Input Rate (NG) 40,000/27,500

45,000/31,000

Max/Min Input Rate (LP)

36,000/26,500

40,000/29,000

Orifi ce Size (NG)

.120 in./3.05 mm .128 in./3.25 mm

Orifi ce Size (LP)

.068 in./1.73 mm .073 in./1.85 mm

B. Ceramic Glass Specifi cations

This appliance is equipped with 5 mm ceramic glass.
Replace glass with 5 mm ceramic glass. Please contact
your dealer for replacement glass.

G. Electrical Codes

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the Canadian Electric
Code CSA C22.1.

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.

F. Combustible Materials Specifi cation

Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that can ig-
nite and burn, whether fl ame proofed or not, or plastered
or unplastered shall be considered combustible materials.