beautypg.com

D. mantel and wall projections, Mantels mantel legs or wall projections – Hearth and Home Technologies Direct Vent Gas Appliance CNXT4236IT User Manual

Page 19

background image

Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08

19

Measured from top of hood (in inches)

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

6

10-1/4

11

11-3/4

12-1/2

13-1/4

14

14-3/4

15-1/2

16-1/4

17

17-3/4

18-1/2

19-1/4

20

20-3/4

30 in. minimum

to ceiling

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).

Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions

1 in. (25 mm) min.
to perpendicular wall

A

3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall

B

Mantel Leg or

Perpendicular Wall

Top of
Appliance

Drywall

A

B

Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)

Mantels