F. Install the Flame Solenoid

Gas Control

Valve

Variable

Regulator

Flame Control

Solenoid

Washer

Variable

Regulator

Variable

Regulator

Washer

Plunger

Jam Nut

Nut

Screw

Knob

Solenoid

Figure 12.3 Install the Flame Solenoid

• Remove the screw and knob from the variable regulator

and discard.

• Remove the nut from the regulator and discard.
• Remove the bag containing a washer and blue and red

plungers from the side of the fl ame control solenoid.

• Place washer on fl ame control solenoid.
• Insert the correct plunger (blue - natural gas, red -

propane) into the fl ame control solenoid.

• Thread

the

fl ame control solenoid with correct plunger

into the thread hole in the variable regulator. Turn into
valve approximately two full turns. Do not tighten or
damage may occur.

• Connect orange wires from control box to the fl ame

control solenoid.

G. Hook up the Temperature Sensor Switch
for Fan

• Find the two yellow wires from the WSK-MLT control box

and disconnect them.

• Connect one yellow wire to one jumper wire hanging

from the thermodisc.

• Connect the other yellow wire to remaining jumper wire

hanging from thermodisc.

• See Figure 12.2 for wiring diagram.