beautypg.com

Vent information and diagrams, A. approved pipe, C. use of elbows – Hearth and Home Technologies Direct Vent Gas Appliance CNXT4236IT User Manual

Page 22: B. vent table key, D. measuring standards

background image

Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08

22

Horizontal

Vertical

8-1/2 in.

8-1/2 in.

12 in.

On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run.

A. Approved Pipe

This appliance is approved for use with Hearth & Home
Technologies DVP and/or SLP venting systems. Refer to
Section 16B for vent component information.

DO NOT mix pipe, fi ttings or joining methods from differ-
ent manufacturers.

The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.

WARNING! Risk of Fire or Asphyxiation. This appliance
requires a separate vent. DO NOT vent to a pipe serving a
separate solid fuel burning appliance.

C. Use of Elbows

Diagonal runs have both vertical and horizontal vent aspects
when calculating the effects. Use the rise for the vertical
aspect and the run for the horizontal aspect (see Figure
7.1).
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A
length of straight pipe is allowed between two 45º elbows
(see Figure 7.1).

Figure 7.1 Using Two 45° Elbows

7

7

Vent Information and Diagrams

B. Vent Table Key

The abbreviations listed in this vent table key are used in
the vent diagrams.

D. Measuring Standards

Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.
• Pipe measurements are shown using the effective length

of pipe (see Figure 7.2).

• Horizontal terminations are measured to the outside

mounting surface (fl ange of termination cap).

• Vertical terminations are measured to bottom of

termination cap.

• Horizontal pipe installed level with no rise.

Figure 7.2 Pipe Effective Length

Symbol

Description

V

1

First section (closest to appliance) of vertical length

V

2

Second section of vertical length

H

1

First section (closest to appliance) of horizontal length

H

2

Subsequent sections of horizontal length

Effective

Height/Length

DVP Pipe

(see chart)

Pipe

inches

mm

DVP4

4

102

DVP6

6

152

DVP12

12

305

DVP24

24

610

DVP36

36

914

DVP48

48

1219

DVP6A

3 - 6

76 - 152

DVP12A

3 - 12

76 - 305

Effective Height/Length

SLP Pipe

(see chart)

Pipe

inches

mm

SLP4

4

102

SLP6

6

152

SLP12

12

305

SLP24

24

610

SLP36

36

914

SLP48

48

1219

SLP6A

2 - 6

51 - 152

SLP12A

2 - 12

51 - 305

Effective Height/Length

Effective

Height/Length