Wiring the wall switch – Hearth and Home Technologies Direct Vent Gas Appliance CNXT4236IT User Manual

Page 54

background image

Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08

54

Wiring the Wall Switch

• Install the provided control wire from the fi replace to the

switch location. (Control wire for Heatilator products is
supplied with the fi replace).

NOTICE:

Do not to stress the wire around tight or sharp

corners. Do not run the control wire adjacent to existing
or future phone, data, cable, or electrical lines. The
wire should not come into contact with any part of the
fi replace exterior with the exception of where it exits the
outer wrap.

ORANGE

GREEN

GROUND

BLACK

WHITE

BLACK

AUX

CONNECTION

BLACK

BLACK

GROUND PIGTAIL

GREEN

FLAME HIGH/LOW

AC

PLUG

ORANGE

ORANGE

RED

RED

FLAME ON

ADAPTER WIRES

FLAME

SOLENOID

IPI

VALVE

IPI

MODULE

BROWN

BLACK

FAN

CONNECTION

YELLOW

YELLOW

FRONT VIEW

REAR VIEW

RED

GREEN

YELLOW OR

WHITE

FAN THERMOSTAT

3V DC

BROWN

BROWN

RED

BLACK

BATTERIES

BLACK

RED

K

C

A

L

B

D

E

R

1
2
3
4
5
6
7
8

* May be labeled as “W” or “Y”.

*

de

R

)

E

L

A

M

E

F/

E

L

A

M(

de

R

)

E

L

A

M

E

F/

E

L

A

M(

*

TEMPERATURE

SENSOR SWITCH

Figure 12.2 Intellifi re (IPI) Wiring Diagram

• Feed the wire to the electrical junction box and through

a provided or approved strain relief.

• Connect the wires to the terminals as shown in Figure

12.2. Do not over-tighten.

• Using the screws provided, mount the switch to the

electrical junction box right side up.

• Install provided cover plate using the screws provided.

Do not use a substitute cover even though it may fi t. The
provided one is specifi cally designed for the automatic
(thermostat) function of the unit.