Electrical information, A. wiring requirements, B. intellifire plus – Heat & Glo Fireplace VRT-BZ-P-AUB User Manual
Page 55: Ignition system wiring
55
Heat & Glo • VRT-AUB • 2123-980 Rev. J • 2/13
12
Electrical Information
Figure 12.1 IPI Wiring Diagram /RC300AU
A. Wiring Requirements
NOTICE: This appliance must be installed by a qualified
electrician in accordance with the relevant national and
local regulations.
• Wire the appliance junction box to 220-240 VAC. This is
required for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
220-240 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: The mains supply to the appliance must have
isolation of a minimum 3 mm contact separation in both
poles.
WARNING! Risk of Injury! The gas supply shall be shut
off prior to disconnecting the electrical power and remov-
ing batteries (if installed) before proceeding with any
maintenance to the appliance.
GREEN
(MAIN)
ORANGE
(PILOT)
8K1 WIRE
HARNESS
GROUND
CONTROL MODULE
OPTIONAL ON/OFF
WALL SWITCH
RED
BLACK
BATTERY PACK
6V DC (C X 4)
BROWN
TO OPTIONAL
COMPONENTS
AUX300CE MODULE (OPTIONAL)
240V FAN (OPTIONAL)
FAN
AUX 1
AUX 2
S
I
GROUND
TO CHASSIS
TO AUX300CE
TO JUNCTION
CORD 220-240 VAC
TO CORD ASSEMBLY
120VAC
WALL SWITCH
JUMPER WIRE
MODULE RESET
SWITCH
WIRE ASSEMBLY
OPTIONAL
OPTIONAL
JUNCTION CORD
WHITE
ORANGE
GAS TUBE
FLAME
SENSE
IGNITOR
B. IntelliFire Plus
TM
Ignition System Wiring
• Wire the appliance junction box to 220-240 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus
TM
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the appliance OR install 4 AA cell
batteries (not included) into the battery pack before use.
• An in-line isolation switch must be installed within 1
meter of the fireplace. This is required for servicing and/
or resetting the control module in the event of a control
module LOCK-OUT.