beautypg.com

Heat & Glo Fireplace VRT-BZ-P-AUB User Manual

Page 28

background image

Heat & Glo • VRT-AUB • 2123-980 Rev. J • 2/13

28

Figure 7.8

H

2

H

1

V

V

2

H

V

1

Figure 7.9

Natural Gas • Two 90° Elbows System

V Minimum

H Maximum

1 ft.

305 mm

3 ft.

914 mm

2 ft.

610 mm

6 ft.

1.83 m

3 ft.

914 mm

9 ft.

2.74 m

4 ft.

1.22 m

12 ft.

3,66 m

5 ft.

1.52 m

15 ft.

4.57 m

V1 + V2 + H = Max. 36 ft. (10.97 m) H = Max. 15 ft. (4.57 m)

Natural Gas • Two 90° Elbows System

V Minimum

H1 + H2 Maximum

2 ft.

610 mm

5-1/2 ft.

1.68 m

3 ft.

914 mm

8 ft.

2.44 m

4 ft.

1.22 m

10-1/2 ft.

3,2 m

5 ft.

1.52 m

13 ft.

3.96 m

V1 + V2 + H = Max. 36 ft. (10.97 m) H = Max. 15 ft. (4.57 m)

Propane • Two 90° Elbows System

V Minimum

H Maximum

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

4 ft.

1.22 m

3 ft.

914 mm

6 ft.

1.83 m

4 ft.

1.22 m

8 ft.

2.44 m

5 ft.

1.52 m

10 ft.

3.05 m

V1 + V2 + H = Max. 36 ft. (10.97 m) H = Max. 10 ft. (3.05 m)

Propane • Two 90° Elbows System

V Minimum

H1 + H2 Maximum

2 ft.

610 mm

3-1/2 ft.

1.07 m

3 ft.

914 mm

5 ft.

1.52 m

4 ft.

1.22 m

6-1/2 ft.

1.98 m

5 ft.

1.52 m

8-1/2 ft.

2.59 m

V1 + V2 + H = Max. 36 ft. (10.97 m) H = Max. 10 ft. (3.05 m)

Butane • Two 90° Elbows System

V Minimum

H Maximum

1 ft.

305 mm

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

3 ft.

914 mm

3 ft.

914 mm

4 ft.

1.22 m

4 ft.

1.22 m

5 ft.

1.52 m

5 ft.

1.52 m

V1 + V2 + H = Max. 33 ft. (10.06 m) H = Max. 3-1/2 ft. (1.07 m)

Butane • Two 90° Elbows System

V Minimum

H1 + H2 Maximum

2 ft.

610 mm

1-1/2 ft.

460 mm

3 ft.

914 mm

2 ft.

610 mm

4 ft.

1.22 m

2-1/2 ft.

760 mm

5 ft.

1.52 m

3-1/2 ft.

1.07 m

V1 + V2 + H = Max. 33 ft. (10.06 m) H = Max. 3-1/2 ft. (1.07 m)