HP vs80 User Manual
Page 67

Chapter 4
Diagnostics and Troubleshooting 67
3 0 83
Inventory not valid.
The cartridge inventory is not valid because of
manual changes or previous fatal errors. Update
the inventory using the Re-inventory option in the
or power
cycle.
3 0 84
Source empty.
There is no cartridge in the location where a
cartridge move was issued.
3 0 85
Destination full.
The location where a cartridge move was issued
already contains a cartridge.
3 0 86
Mail slot access rejected.
User attempted to access the mail slot, but media
removal was prevented by the host.
3 0 87
Operation timeout.
A command did not complete in the required
amount of time.
3 0 88
Communications error during
loop-back.
Cycle power on the autoloader and attempt the
operation again. If the error recurs, contact your
technical support representative.
3 0 89
System test timeout.
There was a communication timeout between the
drive and loader during the System Test.
3 0 8F
Recovered loader error.
Loader error recovery successful. Your diagnostic
tool can provide details of the original loader
error.
3 0 90
Mechanical Initialization failure.
The robotics were not able to move to the safe
mechanical initialization position. Manual
intervention is necessary.
3 0 91
Inventory scan failure.
Fatal robotic error occurred during the inventory
scan.
3 0 92
Preposition failed.
Belt positioning error occurred during
'Preposition' command.
3 0 93
Cartridge load error.
A failure occurred while trying to load a
cartridge from the drive to its slot.
Table 5
Error Codes
Error Code
Description
Details