INSTALLATION

CAVITY DIMENSIONS

BE1-48R

BE1-36R

Inches (mm)

Inches (mm)

A

Maximum height of enclosure shell

35 1/2" (902)

35 1/2" (902)

B

Depth of enclosure shell

22 3/4" (578)

22 3/4" (578)

C

Minimum depth for hood swing

3 3/4" (95)

3 3/4" (95)

D

Width of enclosure cavity

45 3/4" (1162)

34 1/2" (876)

E

Height of enclosure cavity

10 1/8" (257)

10 1/8" (257)

f

Depth to gas supply opening

18 1/2" (464)

18 1/2" (464)

G

Height to base of vents

1" (25)

1" (25)

H

Height of opening for access doors/drawers

20" (508)

20" (508)

I

Width of opening for access doors/drawers

46" (1168)

34" (864)

D

E

H

I

G

F

A

B

C

Built-in Construction Details

Standard layout for non-combustible cavity

IMPORTANT!

If installing the grill into a non-combustible enclosure, all combustible construction must still be
outside the 18" (457mm) clearance zone. If your island is made of stucco over the top of wooden
studs, the wood can not be inside the 18 inch clearance zone to combustible, even though the stucco
is what is touching the grill area.

Note: vents are to be located at the left,
right and rear of the enclosure. Minimum
size of all vents is 10x10" (645mm x 645mm)

Note: 4x4” (102 x 102mm)
opening for gas supply line

FIG. 05

Note: the cut-out of each
corner should be a 90°angle
in order for the access doors/
drawers to fit properly.