beautypg.com

Maintenance – Edimax Technology ES-5240G+ User Manual

Page 106

background image

100

5. Maintenance

5-1. Resolving No Link Condition

The possible causes for a no link LED status are as follows:

z

The attached device is not powered on

z

The cable may not be the correct type or is faulty

z

The installed building premise cable is faulty

z

The port may be faulty


5-2. Q&A

1. Computer A can connect to Computer B, but cannot connect to Computer C

through the 24-Port GbE Web Smart Switch.

9

The network device of Computer C may fail to work. Please check the
link/act status of Computer C on the LED indicator. Try another network
device on this connection.

9

The network configuration for Computer C may be something wrong. Please
verify the network configuration on Computer C.

2. The uplink connection function fails to work.

9

Please make sure that ports on the opposing device are connection ports.
Please check if connection ports are used on that 24-Port GbE Web Smart
Switch.

9

Please check the uplink setup of the 24-Port GbE Web Smart Switch to
verify the uplink function is enabled.

3. There is no console interface seen to be built on the device.

9

24-Port GbE Web Smart Switch has no console port, so you cannot use
console interface to connect with 24-Port GbE Web Smart Switch.


4. How to configure the 24-Port GbE Web Smart Switch.

9

User can use an Internet browser such as IE in

Window®

series of

computers to control the web smart functions of 24-Port GbE Web Smart
Switch. First, choose any port on the 24-Port GbE Web Smart Switch. Then,
use IE and type default IP address, 192.168.1.1, to connect to the 24-Port
GbE Web Smart with RJ45 network cable. Finally, the login screen will
appear at once.

9