Configuring the Host Computer for RS-232 Serial Interface

RS-232 Cabling

RS-232 cable pinouts are shown in the table below. For details on RS-232 signal names,
consult the RS-232 Standard documentation.

Origination

(Mod. 8 x 8)

Termination

(DB9S)

Name

Dir

Description

1

8

RTS

Out

Printer is ready to receive data

2

3

RX

In

Data to the printer

3

2

TX

Out

Data from the printer

4

5

GND

--

Signal, earth, and power ground

5

7

CTS

In

Depends on software selection

6

6

DTR

Out

Indicate printer is online

Modular Plug

RS-232 Signal Levels

The serial interface uses standard RS-232 signal levels as shown in the table below:

Signal Level

Input

Output

MARK (1)

-27 V to -5 V

-5 V

SPACE (0)

+5 V to +27 V

+12 V

RS-232 signal levels.