beautypg.com

Lanview leds -5, Table 4‐1, Table 4-1 – Enterasys Networks Enterasys Gold Distributed Forwarding Engine 4H4284-49 User Manual

Page 65

background image

Using LANVIEW

Matrix DFE-Gold Series Modules Hardware Installation Guide 4-5

Table 4-1 LANVIEW LEDs

LED

Color

State

Recommended Action

MGMT

None

Off. This module is NOT the
Management Module.

None.

Green

Solid. This module is the
designated Management
Module.

None.

Amber

Flashing. This is a
temporary indication that the
module is saving data.

None.

CPU

None

Power off.

Ensure chassis has adequate power.

Amber

Blinking. Module in process
of booting.

None.

Solid. Testing.

If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.

Green

Blinking. Image starts
running.

None.

Solid. Functional.

None.

Red

Solid. Processor in reset.

None.

Green
and
Amber

Blinking. Indicates that the
module is in the process of
shutting down.

None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.
While in this state, do not remove any
DFE-Gold module.

Amber
and Off

Alternately (67% on, 33%
off)
. Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.

While in this state, you have 60 seconds
to safely remove the DFE-Gold module
from the chassis.

This manual is related to the following products: