Figure 3‐7, Figure 3‐8 – Enterasys Networks Enterasys Gold Distributed Forwarding Engine 4H4284-49 User Manual
Page 44
Connecting to the Network
3-14 Installation
Figure 3-7 Eight-Wire Crossover Cable RJ45 Pinouts, Connections Between Hub
Devices
1 RJ45 device port
3 RJ45-to-RJ45 crossover cable
2 Other device port
Figure 3-8 Eight-Wire Straight-Through Cable RJ45 Pinouts, Connections
Between Switches and End-User Devices
1 RJ45 device port
3 RJ45-to-RJ45 straight-through cable
2 Other device port
2
1
3
6
4
5
7
8
TX1+
TX2+
RX4-
RX1-
TX4+
RX3-
TX3+
RX2-
TX2+
TX1+
RX3-
RX2-
TX3+
RX4-
TX4+
RX1-
2
1
3
6
4
5
7
8
Б
А
В
TX1+
TX2+
RX4-
RX1-
TX4+
RX3-
TX3+
RX2-
2
1
3
6
4
5
7
8
TX2+
TX1+
RX3-
RX2-
TX3+
RX4-
TX4+
RX1-
2
1
3
6
4
5
7
8
А
В
Б
This manual is related to the following products: