Connecting to the Network

3-12 Installation

3.

Verify that a link exists by checking that the port RX (Receive) LED is ON (flashing 
amber, blinking green, or solid green). If the RX LED is OFF and the TX (Transmit) 
LED is not blinking amber, perform the following steps until it is on:

a.

To view the receive and transmit activity on a group of segments, press the 
GROUP SELECT button (see 

Figure 3‐4

) to step to the group of interest (Groups 1 

through 4). Each time the GROUP SELECT button is pressed, the GROUP LED 
lights up in sequence, indicating which Group is selected. The receive and 
transmit activity for that group of segments is then indicated by the RX and TX 
LEDs for each segment.

b. Verify that the cabling being used is Category 5 UTP with an impedance between 

85 and 111 ohms. If the port is to operate at 100 Mbps, category 5 cabling must be 
used.

c.

Verify that the device at the other end of the twisted pair segment is on and 
properly connected to the segment.

d. Verify that the RJ45 connectors on the twisted pair segment have the proper 

pinouts and check the cable for continuity. Typically, a crossover cable is used 
between hub devices. A straight‐through cable is used to connect between 
switches or hub devices and an end user (computer). Refer to 

Figure 3‐5

 and 

Figure 3‐6

 for four‐wire RJ45 connections. Refer to 

Figure 3‐7

 and 

Figure 3‐8

 for 

eight‐wire RJ45 connections.

Figure 3-4 Connecting a Twisted Pair Segment With RJ45 Connector

1 RJ45 connector

2 RJ45 port connector

3 GROUP SELECT button

1X

G

R

O

U

P
1

11X

RESET

COM

CPU

MGMT

GROUP

SELECT

GROUP

1

2

3

4

1

2

3

4

5

6

7

8

9

10

11

12

Â

RX

TX

4H4282-49

FAST ENET

Б

А