EXP Computer PathBuilder S200 User Manual
Page 28
24
Bridging
Configuring the PathBuilder S200 Series Switch for Bridging Operation
Description:
Represents the timeout value in minutes. The Bad Hello counter is
reset when the timeout expires and can be used to control how
frequently the Hello counter reaches its alarm threshold.
Learn Only Period (used for Ethernet only)
Range:
2 to 604800
Default:
10
Description:
The time in seconds that a bridge is prevented from forwarding
frames after the forwarding is cleared due to a node boot.
Bad Hello Timeout
(continued)
Aging Period (used for Ethernet only)
Range:
2 to 1000000
Default:
10
Description:
Specify the time in seconds that a learned entry in the Forwarding
Table is allowed to remain in the table without being updated
(relearned). If the entry is not updated within this time period, it is
discarded from the table.
Bridge WAN Data Priority (used for Ethernet only)
Range:
EXP, HIGH, MED, LOW
Default:
HIGH
Description:
Specify the transmission priority of the bridged data over the
WAN.