Fx amplifier • operating manual, Installation – Ashly FX60.2 Multipurpose Installation Network Amplifier with DSP (1 RU, 1/2 Rack) User Manual
Page 8

8
FX Amplifier • Operating Manual
3.2 Free-standing
If not installed in an equipment rack, FX
amplifiers can be placed free-standing on a flat
surface. Adhesive rubber feet are supplied with
all FX models for this purpose.
FX
half-rack
amplifiers can be attached to
the underside of desks or wall mounted using
connecting plate hardware. The adhesive
rubber feet should also be used in these
circumstances to minimize the possibility of
vibration between the amplifier and mounting
surface. Wall and desk mounting is illustrated in
Diagrams 3d and 3e
.
It is important in any free standing installation
that airflow through the amplifier’s side panel
mounted fans and rear panel ventilation
apertures is not compromised by adjacent
items. At least 80mm of free space behind the
amplifier and 25mm along at least one side (for
half-rack units)should be retained at all times.
Note:
Full-rack
models do not have kits for
mounting to a wall or underneath a table,
they can only be used free-standing or rack-
mounted.
Installation
Mounting Plate +
2 x M3 x 6 countersunk
Adhesive Foot
4 positions
Diagram 3d
Ashly Flush Wall/Table-Mount Kit, *FATWB
FX amplifier with desk/wall Mounting Plate and adhesive feet.
2 positions and 4 positions.
Diagram 3e
FX amplifier
wall and under-desk mount
*Mounting kits shown are
available options and are
sold separately.