Ashly FX60.2 Multipurpose Installation Network Amplifier with DSP (1 RU, 1/2 Rack) User Manual
Page 20

20
FX Amplifier • Operating Manual
11. Amplifier Specifications, FX500 Models
Model
FX 500.2
FX 500.4
Output Channels
2 Low-Z or 1 Hi-Z
4 Low-Z or 2 Hi-Z
Output power @ 2Ω
2 x 500W (SE)*
4 x 500W (SE)
Output power @ 4Ω
2 x 500W (SE)
1 x 1000W (BTL)**
4 x 500W (SE)
2 x 1000W (BTL)
Output power @ 8Ω
2 x 250W (SE)
1 x 500W (BTL)
4 x 250W (SE)
2 x 500W (BTL)
Output power @ 25V
†
2 x 320W (SE)
†
4 x 320W (SE)
†
Output Power @ 70V
1 x 1000W (BTL)
2 x 1000W (BTL)
Output Power @ 100V
1 x 1000W (BTL)
2 x 1000W (BTL)
Total System Power
1000W
2000W
Power Consumption
550W
1100W
Thermal Output (BTU/hr,
1/8th Full Power, 2Ω Load)
225
436
Output Voltage
65Vp/130Vpp
(SE unloaded)
130Vp/260Vpp
(BTL unloaded)
65Vp/130Vpp
(SE unloaded)
130Vp/260Vpp
(BTL unloaded)
Weight
5.9 kg (13 lbs)
7.4 kg (16.3 lbs)
Dimensions
88 x 440 x 332 mm (3.5 x 17.3 x 13.1 in)
Output Circuitry
Class D - full bandwidth PWM modulator with ultra-low distortion
Output Voltage
70 Vp / 140 Vpp (unloaded) / Bridged 140 Vp / 280 Vpp (unloaded)
Signal To Noise-Ratio
> 108 dB (A-weighted 20 Hz - 20 kHz 8 Ω load)
THD+N (typical)
< 0.05 % (20 Hz - 20 kHz 8 Ω load 3dB below rated power)
Frequency Response
20 Hz - 20 kHz (+0/-0.5 dB (8 Ω load 3dB below rated power)
Protection Circuits
Short Circuit, Output DC, Undervoltage, Temperature, Overload protection
Power Supply
Universal mains switch mode power supply with Power Factor Correction (PFC) and integral standby converter
Operating Voltage
Universal Mains, 100-240V, 50Hz-60Hz
Standby Consumption
< 0.5W
Accessories
2x rack ears, 4x adhesive feet (included), WR-1 & WR-1.1 GPIO Remote Volume Control (sold separately)
Power Ratings
1% THD @ 120VAC and 230VAC
*SE - conventional, Single Ended output mode. **BTL - Bridge-Tied Load output mode.
†
For 25V output, set DSP output limiter threshold at 25V using RMS voltage setting.