beautypg.com

21 system settings, 1 language setting, 2 system time and date – ARRI ALEXA Mini LF Ready to Shoot V-Mount Set (LPL) User Manual

Page 97: 3 button and display settings, 4 fan settings, 5 battery warning, System settings, Language setting, System time and date, Button and display settings

background image

System Settings

97

21 System Settings

21.1 Language Setting

1. Select

MENU > System > Language

.

2. Set the language to either English or Chinese (simplified).

21.2 System Time and Date

► Select

MENU > System > System Time + Date

to set the system time and date.

Note:

Timezone

and

Daylight Saving Time

do not change time and date settings. They are stored

as metadata in the recorded clips.
Note: System Time and Date are reset after a camera software update.

21.3 Button and Display Settings

► Select

MENU > System > Buttons + Display

.

Following options are available:

Display Style
Button Brightness

Choose between day mode and night mode.
Adjust the brightness of camera and MVF buttons from 0 to 4 (0 = off)

21.4 Fan Settings

Select to set the fan mode to

Low Noise

for locations with ambient temperatures up to 30°C (86°F).

For locations with ambient temperatures higher than 30°C (86°F), set to

Rec Low

. When the fan is set

to Rec Low, it will run at a high rate when the camera is in Standby, and run at a low rate when the

camera is recording.
► Select

MENU > System > Fan Mode

.

Following options are available:

Rec Low

Increases fan speed during standby to cool the camera. Minimizes fan

speed/noise during recording.
Note: Ideal in an environment warmer than 30 °C (86 °F).

Low Noise

Minimizes fan noise during standby and recording.
Note: With data rates above 100 MB/s (due to fps/codec setting), the fan

speed automatically increases to prevent the recording media from over-

heating.

21.5 Battery Warning

You can adjust the voltage level at which a power warning is displayed for the power source connected

to the BAT connector. The level can be adjusted to match the battery type used. The default warning

value is 13.5 V.
► Select

MENU > System > Power > BAT In Warning

and set the warning level between 11.0 V and

34.0 V.
When the power source reaches the defined voltage level the battery display on the HOME screen

and in the status info of the viewfinder and SDI outputs start flashing.