beautypg.com

ARRI ALEXA Mini LF Ready to Shoot V-Mount Set (LPL) User Manual

Page 76

background image

Monitoring

76

Configuration of Overlays

1. Select

MENU > Monitoring > EVF/Monitor > EVF Overlays

.

Select

MENU > Monitoring > EVF/Monitor > Monitor Overlays

.

Select

MENU > Monitoring > SDI > SDI Processing > SDI Overlays

.

Following settings are available:

Frame Lines

Sets frame lines on or off. Used as a framing reference tool with

typically an image frame, a center mark and aspect ratio. For infor-

mation on setting frame lines, see "Setting frame lines".

Frame Line Shading

Applies an outside shading to the area between the frame line and

the remaining active image area.

Center Mark

Sets the center mark between

Off

,

Dot

,

Small Dot

,

Cross

or

Small

Cross

.

Surround Mask

Select to adjust the surround mask settings. If surround view is set

to On, it must be separated from the recorded image area to allow

proper framing, either as black line, colored line, or semi transpar-

ent with 25, 50, 75 or 100% percent opacity (opacity selection is not

available for the MVF-2 flip-out monitor).

Status Info

Only for EVF and SDI. Sets camera status overlays between

Off

,

Overlay

(status on the active image), or

Safe

(status outside the ac-

tive image).

Configuration of Status Info Components

1. Select

MENU > Monitoring > EVF/Monitor > EVF Overlays > Status Components.

Select

MENU > Monitoring > SDI > SDI Processing > Overlays > Status Components

.

2. Following settings are available:

Info 1

Enables/disables the top and bottom section of the status info.

Info 2

Enables/disables the left and right section of the status info.

Timecode

Enables/disables display of the timecode on the bottom right of the

image.

Audio

Enables/disables display of the audio levels located on the lower

right side of the image.

Lens Data

Enables/disables iris and focal length readings.

Lens Focus Distance

Sub-option of lens data setting. Enables/disables display of focus

distance readings (19), located on the lower left corner of the im-

age.

UDM

Sub-option of lens focus distance setting. Enables/disables display

of distance readings from the Ultrasonic Distance Measure UDM-1

(in combination with LCUBE CUB-1). Located above the lens focus

distance overlay.

This manual is related to the following products: