Back

LAN (network) terminal (RJ-45)

Network communication and PoE power

supply are provided using the network cable

(category 5e or higher, shielded twist pair).

For more information on the connection,

refer to the instruction manual of the PoE

power supply device.

The LED on the left lights up in orange when

the network is connected by 1000BASE-TX,

or in green when connected by 100BASE-TX.

It is turned off when the network is

connected by 10BASE-T or the network is

disconnected.

The LED on the right flashes during data

transfer.

Factory settings for network

IP address: 192.168.0.100

Subnet mask: 255.255.255.0

Default gateway: 192.168.0.254

Name: CAM1

User name: admin

Password: Admin_1234

Note

When connecting this product to a network,

connect via a system that provides a

protection function, such as a router or

firewall. If connected without such

protection, security issues may occur.

AUDIO OUT terminal

Output LINE level to connect an audio

device.

AUDIO IN terminal

Input for commercially-available MIC or LINE

to connect an audio device.

Tip

Switch between MIC and LINE input, as

indicated on “Connecting to commercially-

available microphones etc.” (page 21).

12 V

(DC power input) terminal

Connect the AC adapter (supplied).

Note

Do not use any AC adapter other than the

supplied AC adapter. Otherwise, a fire or

malfunction may occur.

POWER lamp

Lights in green when the camera is

connected to an outlet using the supplied AC

adapter and power cord, or when power is

being supplied by connecting the camera

and PoE power supply device with a LAN

cable.

VISCA RS-232 IN terminal

Connect with an remote controller (not

supplied).

When you connect multiple cameras,

connect it to the VISCA RS-232 OUT terminal

of the previous camera in the daisy chain

connection.

VISCA RS-232 OUT terminal

When you connect multiple cameras,

connect it to the VISCA RS-232 IN terminal of

the next camera in the daisy chain

connection.

HDMI output terminal

Supplies the images as an HDMI video

signal.

Reset switch

Press the switch for 5 seconds or longer to

return to the factory default.