1 module data – ProSoft Technology MVI56-GEC User Manual
Page 36
Ladder Logic
MVI56-GEC ♦ ControlLogix Platform
User Manual
Generic ASCII Ethernet Communication Module
Page 36 of 108
ProSoft Technology, Inc.
October 8, 2010
3.1
Module Data
All data related to the MVI56-GEC is stored in a user defined data type.
The following Table depicts the Object Hierarchy of the Tags used along with
Data Type of the Tags.
OBJECT HIERARCHY
DATA TYPE
Module
GECModule
Cfg
GECConfig
ModName
SINT[80]
Password
SINT[20]
Servers
GECServer[5]
Enable
INT
ServicePort
INT
ConnTimeout
INT
ConnCloseType
INT
SwapRx
INT
SwapTx
INT
Wattcp
GECWattcp
My_IP
INT[4]
Netmask
INT[4]
Gateway
INT[4]
GNetwork
INT[4]
GMask
INT[4]
Stat
GECInStat
PassCnt
INT
Product
INT[2]
Rev
INT[2]
OP
INT[2]
Run
INT[2]
BlkErrs
GECBlkStat
Read
INT
Write
INT
Parse
INT
Err
INT
Server
GECServerStat[5]
Enabled
INT
State
INT
IP
INT[2]
- ILX69-PBS (102 pages)
- MVI69E-LDM (130 pages)
- ILX69-PBM (124 pages)
- MVI69L-MBTCP (152 pages)
- PS69-DPS (108 pages)
- MVI69E-MBTCP (150 pages)
- MVI69L-MBS (154 pages)
- MVI69E-MBS (162 pages)
- PS69-DPM (130 pages)
- MVI69-FLN (137 pages)
- MVI69-DFNT (167 pages)
- MVI69-GEC (86 pages)
- MVI69-PDPS (96 pages)
- MVI46-S3964R (80 pages)
- MVI46-S3964R (78 pages)
- MVI46-DNPSNET (119 pages)
- MVI69-ADMNET (122 pages)
- MVI56-104S (188 pages)
- MVI69-ADM (342 pages)
- MVI69-MCM (167 pages)
- 5307-MBP-HART (169 pages)
- MVI69-PDPMV1 (225 pages)
- MVI69-GSC (102 pages)
- MVI69-DNP (129 pages)
- MVI69-DFCM (117 pages)
- MVI69-103M (131 pages)
- PC56-OPC (34 pages)
- MVI46-MBP (101 pages)
- MVI69-101S (149 pages)
- MVI56-103M (152 pages)
- MVI56-DFCMR (113 pages)
- MVI56-DNP (193 pages)
- MVI56-LTQ (98 pages)
- ILX56-MM (112 pages)
- MVI56-BAS (234 pages)
- MVI56-DFCM (106 pages)
- MVI46-PDPS (88 pages)
- MVI56E-MNETCR (159 pages)
- MVI46-AFC (316 pages)
- MVI56E-MNETC (183 pages)
- MVI56E-GSC/ GSCXT (140 pages)
- MVI56-PDPMV1 (255 pages)
- MVI46-MNETC (153 pages)
- CLX-APACS (53 pages)
- MVI56E-MNET/MNETXT (181 pages)