ProSoft Technology MVI56-GEC User Manual
Page 19
![background image](https://www.manualsdir.com/files/866134/content/doc019.png)
MVI56-GEC ♦ ControlLogix Platform
Start Here
Generic ASCII Ethernet Communication Module
User Manual
ProSoft Technology, Inc.
Page 19 of 108
October 8, 2010
5 On the Connected To Go Online dialog box, click the G
ENERAL
tab. This tab
shows information about the processor, including the Revision (firmware)
version. In the following illustration, the firmware version is 17.2.
1.7.2 Selecting the Slot Number for the Module
This sample application is for a module installed in Slot 1 in a ControlLogix rack.
The ladder logic uses the slot number to identify the module. If you are installing
the module in a different slot, you must update the ladder logic so that program
tags and variables are correct, and do not conflict with other modules in the rack.
Changing the slot number
1 In the Controller Organization list, select the module and then click the right
mouse button to open a shortcut menu.
2 On the shortcut menu, choose P
ROPERTIES
. This action opens the Module
Properties dialog box.
3 In the Slot
field, use the spinners on the right side of the field to select the slot
number where the module will reside in the rack, and then click OK.
RSLogix will automatically apply the slot number change to all tags, variables
and ladder logic rungs that use the MVI56-GEC slot number for computation.