ProSoft Technology MVI69-HART User Manual
Page 75
MVI69-HART ♦ CompactLogix Platform
Diagnostics and Troubleshooting
HART Multi-drop Master Communication Module
User Manual
ProSoft Technology, Inc.
Page 75 of 169
March 29, 2012
Displaying Timing Marks in the Data Analyzer
You can display timing marks for a variety of intervals in the data analyzer
screen. These timing marks can help you determine communication-timing
characteristics.
Key
Interval
[5]
1 milliseconds ticks
[6]
5 milliseconds ticks
[7]
10 milliseconds ticks
[8]
50 milliseconds ticks
[9]
100 milliseconds ticks
[0]
Turn off timing marks
Removing Timing Marks in the Data Analyzer
Press [0]
to turn off timing marks in the Data Analyzer screen.
Viewing Data in Hexadecimal Format
Press [H]
from the Database View menu
to display the data on the current page
in hexadecimal format.
Viewing Data in ASCII (Text) Format
Press [A]
from the Database View menu to display the data on the current page
in ASCII format. This is useful for regions of the database that contain ASCII
data.
Starting the Data Analyzer
Press [B]
to start the data analyzer. After the key is pressed, all data transmitted
and received on the currently selected port will be displayed. The following
illustration shows an example.