ProSoft Technology MVI69-DFNT User Manual
Page 128

Reference
MVI69-DFNT ♦ CompactLogix or MicroLogix Platform
User Manual
EtherNet/IP Client/Server Communication Module
Page 128 of 167
ProSoft Technology, Inc.
May 14, 2014
5.3.4 SLC 5/05 Processor
The module can be used to receive messages from a SLC 5/05 containing an
Ethernet interface. The module supports both read and write commands. A
discussion of each operation is provided in the following topics.
SLC5/05 Write Commands
Write commands transfer data from the SLC processor to the DFNT module. An
example rung used to execute a write command is shown in the following
diagram:
Set the R
EAD
/W
RITE
parameter to W
RITE
.
The module supports a T
ARGET
D
EVICE
parameter value of 500CPU
or PLC5.
In order to complete the configuration of
the MSG instruction, select the S
ETUP
S
CREEN
area of the MSG object. This
displays the following dialog box.